Ostomy skin barrier

Hollister New Image Convex FlexWear Skin Barrier without Tape

Hollister New Image FlexWear is a convex, standard wear skin barrier without a tape border for a two-piece pouching system. Choose the complete flange and opening combination for the matching pouch.

Item # HLL15403Vendor Hollister
$51.40
  • Convex FlexWear barrier
  • Cut-to-fit or pre-sized openings
  • Box of 5
1Select Size
2Select Quantity
3Choose how to buy

Fast & free shipping on orders $100+

In stock and ready to ship

Secure checkoutProtected payment experience
Clear product optionsSize and pack choices are clearly labeled
Confidential deliveryDiscreet outer packaging
Product guidanceSupport from a real person
Fast shippingFree 1–2 day shipping on $100+
Discreet deliveryPlain packaging, always
Easy returns30 days to make it right
Human helpCall a product specialist

Product benefits

Designed for your care routine

Compare the opening type and size, then check the barrier's product system.

01

Convex FlexWear design

This convex barrier uses FlexWear hydrocolloid adhesive for standard wear.

02

Match the flange and opening

Cut-to-fit options can be trimmed within their specified limit. Pre-sized options arrive with a fixed opening. Select the flange and opening together.

03

No tape border

Every item in this family is listed without a tape border. Each box contains 5 skin barriers.

Product information

Details and specifications

A convex, standard-wear skin barrier for Hollister New Image two-piece pouching systems. FlexWear provides moderate adhesion for more than one day of wear, while the integrated floating flange helps reduce pressure on the abdomen when attaching a pouch. This family does not have a tape border.

Product features

  • Convex FlexWear standard-wear skin barrier
  • Integrated floating flange without a tape border
  • Cut-to-fit and pre-sized opening choices
  • Pairs with New Image pouches that use the same flange size

How to choose

Each size choice combines the flange size, opening, and fit style for one real Hollister item. Match the flange size to a compatible New Image pouch, then choose the opening for the measured stoma.

  • Cut-to-fit: Trim the opening within the product's marked cutting area.
  • Pre-sized: Choose the listed fixed opening; no trimming is required.

Package information

Sold as a box of 5 skin barriers.

Confirm the selected flange size, opening, and fit style before ordering. Follow the Instructions for Use supplied with the product.

Hollister New Image Convex FlexWear skin barrier without tape, item 15402 PRODUCTAT A GLANCE

Product details

A convex barrier for a matching two-piece pouch

FlexWear skin barriers have an attached flange and are designed for use with a corresponding pouch of the same flange size. The barrier is made from hydrocolloid skin adhesive and polymer/copolymer plastics and is not made with natural rubber latex. This family contains both cut-to-fit and pre-sized openings, all without tape.

Choose your option

Item and package guide

Match the complete selection and item below. Confirm the size, shape, and quantity before ordering.

Hollister FlexWear instructions - English on page 1
Available selection Milliken item Item #
1-3/4" Flange / 1" Cut-to-Fit / Box of 5 HLL15402
2-1/4" Flange / 1-1/2" Cut-to-Fit / Box of 5 HLL15403
2-3/4" Flange / 2" Cut-to-Fit / Box of 5 HLL15404
1-3/4" Flange / 7/8" Pre-Sized / Box of 5 HLL15503
1-3/4" Flange / 1" Pre-Sized / Box of 5 HLL15504
2-1/4" Flange / 1-1/8" Pre-Sized / Box of 5 HLL15505
2-1/4" Flange / 1-1/4" Pre-Sized / Box of 5 HLL15506

Customer reviews

See what customers say.

Product questions

Use and care information

For cut-to-fit items, measure and trim the opening as shown in the manufacturer diagrams. Pre-sized items are already cut. Apply the barrier and attach the matching pouch according to the supplied instructions.

Remove the used barrier gently while supporting the surrounding skin. Dispose of it according to local requirements; do not flush it.

For single use. Reuse or attempts to clean, disinfect, sterilize, or reprocess the barrier may impair adhesion and cause odor or leakage.

An incorrect opening or leakage can cause skin damage, including irritation, broken skin, rash, or redness, and may reduce wear time.

Apply to clean, dry, intact skin. Avoid oils and lotions where the barrier will adhere because they can weaken adhesion.

Stoma shape, output, skin condition, and abdominal contours affect fit. Contact a stoma care nurse or healthcare professional for pouching or skin-irritation concerns. Report a serious product-related injury to the manufacturer or distributor and the relevant local authority.

Confirm the selected flange size, opening, and fit style before ordering. Follow the Instructions for Use supplied with the product.

Follow the complete instructions and safety information supplied with your product. This page does not replace those instructions.

Which pouch does this barrier fit?

Use a compatible Hollister New Image pouch with the same flange size as the selected barrier. The opening measurement describes the fit around the stoma; it does not replace the flange measurement.

What does the cut-to-fit measurement mean?

The catalog lists the cut-to-fit number as the maximum stoma size for that item. It is not a pre-sized opening. Measure the stoma and follow the supplied measuring and cutting instructions.

How should I choose the barrier shape?

Barrier shape and fit depend on the stoma and surrounding skin. Ask a stoma care nurse or healthcare professional for help choosing a suitable fit.

The right supplies, right on time

Make one daily essential easier to reorder.

Hollister FlexWear instructions - English on page 1